Represents the type of output data source.
enum Go2OutputDataSourceType { GO2_OUTPUT_DATA_SOURCE_TYPE_NONE = 0, GO2_OUTPUT_DATA_SOURCE_TYPE_PROFILE = 1, GO2_OUTPUT_DATA_SOURCE_TYPE_PART = 2, GO2_OUTPUT_DATA_SOURCE_TYPE_VIDEO = 3, GO2_OUTPUT_DATA_SOURCE_TYPE_VALUE = 4, GO2_OUTPUT_DATA_SOURCE_TYPE_DECISION = 5, GO2_OUTPUT_DATA_SOURCE_TYPE_RAW_PROFILE = 6, GO2_OUTPUT_DATA_SOURCE_TYPE_PROFILE_INTENSITY = 7, GO2_OUTPUT_DATA_SOURCE_TYPE_RAW_PROFILE_INTENSITY = 8, GO2_OUTPUT_DATA_SOURCE_TYPE_PART_INTENSITY = 9, GO2_OUTPUT_DATA_SOURCE_TYPE_RANGE = 10, GO2_OUTPUT_DATA_SOURCE_TYPE_RANGE_INTENSITY = 11 };
|
Members |
Description |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_NONE = 0 |
No output source. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_PROFILE = 1 |
Output source is profile data. Supported only on 2x00 series sensors. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_PART = 2 |
Output source is part data. Supported only on 2x00 and 3x00 series sensors. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_VIDEO = 3 |
Output source is video data. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_VALUE = 4 |
Output source is measurement value data. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_DECISION = 5 |
Output source is measurement decision data. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_RAW_PROFILE = 6 |
Output source is raw profile data. Supported only on 2x00 series sensors. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_PROFILE_INTENSITY = 7 |
Output source is profile intensity data. Supported only on 2x00 series sensors. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_RAW_PROFILE_INTENSITY = 8 |
Output source is raw profile intensity data. Supported only on 2x00 series sensors. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_PART_INTENSITY = 9 |
Output source is part intensity data. Supported only on 2x00 series sensors. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_RANGE = 10 |
Output source is range data. Supported only on 1x00 series sensors. |
|
GO2_OUTPUT_DATA_SOURCE_TYPE_RANGE_INTENSITY = 11 |
Output source is range intensity data. Supported only on 1x00 series sensors. |
Go2Api.h